Square D

General Duty UL listed safety disconnect switches are rated outdoor NEMA 3R with external lockable switch handle. These safety switches serve as service disconnects and overcurrent devices for AC or DC systems rated to 250 Volts. Switches include main lugs, neutral bus and ground screw. Typical use is to satisfy NEC code that any electrical service entering a residence (grid, PV, generator) must have it's own disconnect on the exterior of the residence. 100 amp model may be recommended to accept large cables from PV array, with a fuse reducer to allow fuse matched to the array. Fuses sold separately.

2 pole 30A Class R Switch
3 pole 30A Class R Switch
2 pole 60A Class R Switch
3 pole 60A Class R Switch
2 pole 100A Class R Switch

Class R fuses (UL listed 125VDC/250VAC):

20 amp, 30 amp, 40 amp, 50 amp, 60 amp, 80 amp, and 100 amp

Class R Fuse Reducer:

263R
Up to 30 amp in 60 amp space

216R
40 - 60 amp in 100 amp space


AC Load Centers

UL listed, 120/240 VAC single-phase,main lug load centers are used for distribution of AC load circuits. Intended for use with 'QO' type circuit breakers. Includes solid neutral and cover. Ground bar sold separately. NEMA 3R for outdoor use.

LCR2-40
2 spaces, 40 amps

LCR3-100
3 spaces, 100 amps

LCR6-100
6 spaces, 100 amps


AC Bypass Breaker

UL listed, 120/240 VAC three-phase, main lug load centers can be used for distribution of AC generator power to bypass an AC inverter output circuit to household loads as a backup. Fully assembled. Includes solid neutral, main lugs, mechanical breaker interlock (assures one on/one off), and type 'QO' 60 amp circuit breakers. Indoor enclosure and cover.

BPB-60 .. 60 amp
BPB-30 .. 30 amp

Grounding Kits

Field installable grounding bars for 240 VAC rated enclosures.

60 amp, #8-#4 AWG with 3 terminals

100 amp #2-#2/0 AWG with 6 terminals


QO Breakers

UL listed, 120/240 VAC, 48 VDC, single pole 'QO' breakers feature a 'visi-trip' indicator and are intended for plug-in installation into load centers. Accept #14 to #8 AWG.

QOU Breakers

UL listed, 120/240 VAC, 48 VDC, single pole 'QOU' breakers feature a 'visi-trip' indicator and are intended for flush or surface mounting with reversible feet, or DIN rail mount. Includes mounting feet for convenient panel attachment. Accept #14 to #2 AWG.

The QO110 are available in 10 amp, 15 amp, 20 amp, 30 amp, 40 amp, 50 amp and 60 amp

Looking for more Electrical Supplies Online? Go to Electrical Supplier Links.

POLICIES
All items are new with full manufacturers warranties, unless otherwise noted. CSE guarantees all items to be as advertised, subject to typographic errors. Any item may be returned for a refund within 30 days. Returns require return authorization from CSE. Returns may be subject to a 15% restocking fee. Shipping charges are not refundable.
Any back-ordered items may be cancelled at any time before shipping for full credit.
Colorado residents add 2.9% sales tax.

1-800-766-7644
     

INFO@COSOLAR.COM

DISCONNECTS

OUTBACK PSDC / PSAC

OUTBACK COMBINERS

BASIC / FUSES

SQUARE D

TRACE DC SERIES

 




colorado solar electric
Copyright 2002 Colorado Solar Electric
(800)766-7644
www.cosolar.com